Autel MaxiSys MS906 Touch Screen No Response after Screen Replacement

One customer gave feedback that his Autel MaxiSys MS906 wont response to any clicks on the touch screen after replacing it.

autel-maxisys-ms906-touch-screen-no-response-after-screen-replacement-1

autel-maxisys-ms906-touch-screen-no-response-after-screen-replacement-2

autel-maxisys-ms906-touch-screen-no-response-after-screen-replacement-3

Her Cardiagtool technician gave the

Solution:

 

Step 1

Check if R375 Resistor is removed.

autel-maxisys-ms906-touch-screen-no-response-after-screen-replacement-4

Step 2

If the resistor is removed and the problem remains, flash MaxiSys MS906.

1)Download the compressed file and unzip it, will see the ‘autel_906’ folder. (Click to Download MS906 Flash Software Package)

2)Copy the whole ‘autel_906’ folder to blank TF card root menu. (The TF card should be formatted to FAT32)

3)Plug the TF card to MS906 card slot.

4)Power on the MS906 and it will to go to flash process automatically.

 

Note:

This device got out of update subscription since Nov. 2019, so the latest operating system may be required, which needs to renew subscription.

 

https://www.cardiagtool.co.uk/

Email:sales@cardiagtool.co.uk

Whatsapp: +86 15002705698